Contact Us

Brand Vertiv UPS System Industrial UPS Vertiv Liebert Make 400 KVA 3:3 Phase Industrial On-Line UPS With In Built Isolation Transformer

Vertiv Liebert Make 400 KVA 3:3 Phase Industrial On-Line UPS With In Built Isolation Transformer

UPS System Industrial UPS

Price: 2537000

You save 1774720

Model HI Pulse U 400 KVA

Reset default

Specification

Output Specification
Output Capacity (KVA )
400 KVA
Output Capacity (KW )
360 KW
Output Power Factor
0.99 Power Factor
Output Phase
3 Phase
Output Voltage
400 Volt
Other Output Voltage
380 Or 415 Volt
Efficiency at Full Load
>0.99 %
Output Voltage Distortion
<3 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
< 3% linear load and <5% non-linear load
Transfer Time
<0 ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 5-wire (3PH + N + G)
Bypass
Built-in Static Bypass
Overload Capacity
150% for 1 minute 125% for 10 minutes
UPS Parallel Upto
Optional
Input Specification
Input Voltage
400 Volt
Other Input Voltage
380 - 415 Volt
Input Phase
3 Phase
Other Input Phase
- Phase
Input frequency
50 Or 60 Hz
Input frequency Range
40 - 70 Hz
Input Voltage Range (Output Derated)
150 - 342 Volt
Input voltage range for main operations
342 - 477 Volt
Input Power Factor
>0.99 Power Factor
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input Protection
Fuse
Input Voltage THD
<3 %
Input Short Circuit Current (Maximum)
kAmps.
Input Current (Maximum)
Amp.
Batteries & Runtime
Battery Position Option
External
Battery Circuit Breaker
Optional
Approved Battery Capacity (AH)
150 - 200 Amp.
Maximum Charger Capacity
100 Amp.
Battery DC Bus
408 VDC
Battery Type Compatibility
Sealed Maintenance Free (SMF) / Valve Regulated Lead Acid (VRLA) type, Flooded / tubular / vented type
Communication & Management
Control panel
Touch Screen LCD User Interface
SNMP Management
Optional
Power Management Software
In-Built
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
Decibal
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
- Meters
Storage Temperature
-25 - 55 °C
Storage Relative Humidity
0 - 95 %
Protection Class
IP20
Compliances
Compliance
BIS
Other Environmental Compliance
Compliant
Other Specifications
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Surge Protection
Yes

Documentation

Item Catalogue
Hipulse U-200K
pdf