Contact Us

Brand DELTA UPS System On Line UPS Delta Make 1 KVA On-Line UPS (INX Series)

Delta Make 1 KVA On-Line UPS (INX Series)

UPS System On Line UPS

Price: 23364

You save 37052

Model Amplon INX 1kVA(VLB)

Reset default

Specification

Output Specification
Output Capacity (KVA )
1 Kva
Output Capacity (KW )
0.9 Kw
Output Power Factor
0.8 Power Factor
Output Phase
1 Phase
Other Output Phase
Output Voltage
220 Volt
Other Output Voltage
230 Or 240 Volt
Efficiency at Full Load
>88 %
Output Voltage Distortion
<2 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<3 %
Transfer Time
<0 Ms
Output Waveform type
Sine Wave
Output Connections
3 Pin Indian Socket (04 Nos.)
Bypass
Internal Bypass (automatic & manual)
Overload Capacity
Optional
UPS Parallel Upto
Input Specification
Input Voltage
220 Volt
Other Input Voltage
230 Or 240 Volt
Input Phase
1 Phase
Other Input Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
145 - 280 Volt
Input voltage range for main operations
110 - 280 Volt
Input frequency Range
40 - 70 Hz
Input Power Factor
>0.99 None
Input Connections
3-Pin 6A Indian Socket
Input Protection
Batteries & Runtime
Internal Battery Capacity (VAH)
Approved Battery Capacity (AH)
7 - 200 Amp.
Battery DC Bus
36 - Vdc
Maximum Charger Capacity
16 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Batteries Recharge Time upto 90%
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
In-Built
Power Management Software
In-Built
Interface Port(s)
DB-9 RS-232, Smart-Slot
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
<50 Decibal
Physical
Maximum Height
220 Mm
Maximum Width
145 Mm
Maximum Depth
282 Mm
Shipping Height
Shipping Width
Shipping Depth
Net Weight
4.4 Kg
Shipping weight
Kg
Rack Height(U)
Colour
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
5 - 95 % Rh
Operating Elevation
Storage Temperature
-20 - +60 °C
Storage Relative Humidity
Storage Elevation
- Meters
Compliances
Compliance
IS 16242 (Part1): 2014
Approvals
IS 16242 (Part1): 2014
Other Environmental Compliance
IS 16242 (Part1): 2014
Other Specifications
Technology
Double Conversion Online
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Surge Protection
Yes

Features

Amplon INX Series Features
Availabilty
True online double-conversion topology and zero transfer time to battery ensure high reliability
High input power factor corrector (> 0.99) for controlled sine wave AC output
Cold-start capability with temporary battery power when the utility power is out
Automatic bypass to transfer the load on mains in case of overload & internal fault
Battery deep discharge protection
Flexibility
Excellent local communications through user friendly LCD display
Intelligent management software connectivity via RS232, mini slot or USB port
Three multi-functional buttons for the operation and selection of parameters
Cost of Ownership
Protection against over voltage; charger working even when the input switch is in off position
ECO mode to provide energy cost savings
Wide input voltage range to reduce the chance of using the battery and to extend battery life
Intelligent battery management sustaining battery life and performance
Fan speed control by load level and room temperature to optimize performance

Documentation

Item Catalogue
INX Series 1-3 kVA UPS - Extended Runtime Models Catalogue
pdf
Item Manuals and Warranties
INX Series 1-3 kVA UPS - Extended Runtime Models User Manual
pdf

Options