Contact Us

Brand Vertiv UPS System On Line UPS Liebert Make 1 KVA 1:1 Phase On-Line UPS ( MT+ CX LB 16A )

Liebert Make 1 KVA 1:1 Phase On-Line UPS ( MT+ CX LB 16A )

UPS System On Line UPS

Price: 27140

You save 19824

Model GXT MT+ CX 1K LB 16A

Reset default

Specification

Output Specification
Output Capacity (KVA )
1 Kva
Output Capacity (KW )
.8 KW
Output Power Factor
.8 Power Factor
Output Phase
1 Phase
Output Voltage
230 Volt
Efficiency at Full Load
> 90 %
Load Crest Factor
3:1
Output Voltage THD
<3 %
Output Waveform type
Sine Wave
Input Specification
Input Voltage
230 Volt
Other Input Voltage
220 Or 230 Volt
Input Phase
1 Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
110 - 280 Volt
Input voltage range for main operations
140 - 285 Volt
Input frequency Range
40 - 70 Hz
Input Power Factor
>0.99
Batteries & Runtime
Battery DC Bus
36 - VDC
Maximum Charger Capacity
16 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Approved Battery Capacity (AH)
17 - 200 Amp.
Communication & Management
Control panel
LCD Display
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
RS-232, USB
Audible noise at 1 meter from surface of unit
<45 Decibal
Physical
Maximum Height
333 Mm
Maximum Width
145 Mm
Maximum Depth
282 Mm
Net Weight
5.6 Kg
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Other Specifications
Technology
Double Conversion Online

Features

GXT MT+ CX 16A Features
General Features
IGBT Based Rectifier
True Online Double Conversion with DSP Control Technology for High Performance and Reliability
New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and trouble shooting
Double Conversion Efficiency upto 90%
Active Input Power Factor Correction 0.99
0.8 Output Power Factor
Wide Input Voltage window (110 - 280 Vac) for Indian Environmental Condition and for Optimized Battery Performance
Configurable Output Voltage (200/208/220/230/240 Vac.)
Generator compatible with wide input
8 Stage extendable charging design for optimized Battery performance
Adjustable battery charging current 2/4/6/8/10/12/14/16 Amps according to battery capacity rating
50/60 Hz automatic frequency converter mode
Intelligent monitoring with standard RS232/USB port plus slot available for RS485/Dry Contact/SNMP card
Inbuilt OVCD (Over Voltage Cut-off device)
Highlights
Remote monitoring is available through USB/RS232 and optional via dry contacts and SNMP
The monitoring option software support TCP/IP with event log and analysis function
Self-diagnosis and protection enable the auto shutdown of the client terminal or server auto shutdown of the client terminal or server under abnormal mains supply or when battery is over discharged
SNMP Manager Card with advanced viewpower software (optional): allows remote Monitoring through RJ45 & manages mulitple UPS from anywhere through internet
Data logging real time dynamic graphs of UPS data, warning notification via audible alarm, broadcast, mobile message, e-mail & SNMP traps
Also supports optional environmental monitoring detector for temperature, humidity and smoke. Password security protection and remote access management

Documentation

Item Catalogue
GXT MT+ CX 1K LB 16A
pdf

Options

Services