Easy UPS 3L 500kVA 400V 3:3 UPS, Startup 5x8
Easy-to-configure, easy-to-use and easy-to-service 500 kVA 3 phase UPS. With its exceptional combination of competitive specifications, compact footprint, and highly available parallel and redundant designs, the EcoStruxure Ready Schneider Electric Easy UPS 3L is the easy choice for business continuity on your shop floor, in your electrical room, or in your data center. Includes 5x8 start-up service.
Includes: Dust filter, Installation manual, Start-up service
Model GVL500KDS

Reset default

Specification

Output Specification
Output Capacity (KVA )
500 KVA
Output Capacity (KW )
500 KW
Output Power Factor
1 Power Factor
Output Phase
3 Phase
Output Voltage
400 Volt
Other Output Voltage
380 Or 415 Volt
Efficiency at Full Load
> 97 %
Load Crest Factor
3:1
Output Voltage THD
< 3% linear load and <5% non-linear load
Bypass
Built-in Static Bypass
Overload Capacity
150% for 1 minute 125% for 10 minutes
UPS Parallel Upto
6 Nos.
Input Specification
Input Voltage
400 Volt
Other Input Voltage
380 - 415 Volt
Input Phase
3 Phase
Input Voltage Range (Output Derated)
323 - 477 Volt
Input voltage range for main operations
323 - 477 Volt
Input Power Factor
0.99
Input Voltage THD
< 3 %
Input Short Circuit Current (Maximum)
35 kAmps.
Batteries & Runtime
Battery DC Bus
432 - 600 VDC
Battery Type Compatibility
SMF/ Li-Ion battery
Battery Position Option
External
Battery Circuit Breaker
Optional
Approved Battery Capacity (AH)
200 - 1000 Amp.
Communication & Management
Control panel
Touch Screen LCD User Interface
SNMP Management
Optional
Power Management Software
In-Built
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
72 Decibal
Physical
Maximum Height
1970 Mm
Maximum Width
925 Mm
Maximum Depth
850 Mm
Net Weight
720 Kg
Colour
White
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Protection Class
IP20
Other Specifications
Technology
Double Conversion Online
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Surge Protection
Yes

Features

Galaxy VL Features & Benefits
Features
Highly efficient,scalable 200 to 500 kVA/kW 3-phase UPS featuring modular, redundant design and low TCO for medium and large data centers and mission critical environments
Galaxy VL is a highly efficient, compact, modular, and scalable 200-500 kW (400 V/480 V) three-phase uninterruptible power supply (UPS) available worldwide that delivers top performance for medium, large, and edge data centers, as well as critical infrastructure in commercial and industrial facilities
Its industry-leading, compact, high-density technology, and fault-tolerant architecture maximize availability, operational efficiency, and critical load protection while minimizing total cost of ownership (TCO). Thanks to patented technologies, this UPS delivers up to 99% efficiency in ECOnversionâ„¢ mode and up to 97% efficiency in double conversion mode.
Galaxy VL’s scalability enables you to pay-as-you grow, reducing both capital investment and TCO. You can buy the power modules you need up-front, and enjoy optimized operating efficiency, then add power modules with Live Swap as demand grows. The modular design also enables N+1 internal redundancy, which multiplies by 10 the system’s availability with no extra footprint
Galaxy VL is compatible with Lithium-ion batteries. With our Schneider Electric Lithium-ion battery solution, classic VRLA, or NiCd batteries, critical loads have highly predictable runtimes.
Galaxy VL is EcoStruxure™ connected to give you peace of mind anytime, anywhere. Start-up service is included to optimize your system’s performance, quality, and safety. With Live Swap, modular design, and superior reliability, Galaxy VL is the ideal backbone for your critical infrastructure
Availability & Flexibility
Parallel-capacity capability
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Modular UPS design
Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.
Robust operation
No power derating in kW up to 40°C or 104°F.
Parallel-redundant capability
Powers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.
Embedded Network Management Card
Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.
Compatible with Schneider Electric's lithium ion battery solution
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability.
Flexible DC bus
Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.
Serviceability
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
EcoStruxure IT Expert
From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. To learn more, visit a target="_blank" href="http://www.ecostruxureit.com"ecostruxureit.com/a.
Multiple levels of service offers
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.
Cost of Ownership
Compact UPS
High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.
High efficiency in double conversion mode
Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.