Contact Us

Brand Socomec UPS System Industrial UPS Socomec Make 100 KVA 3:3 Phase Industrial On-Line UPS

Socomec Make 100 KVA 3:3 Phase Industrial On-Line UPS

UPS System Industrial UPS

Price:

You save 0

Superior reliability and performance

The solution for
• Small & medium-sized data centres
• Banks
• Medical facilities
• Medical devices
• Telecom & media infrastructure
• Transport
• Control rooms

Advantages
Superior design and reliability
• Oversized design margin: reliability first.
• Certified seismic resistance.
• Superior and officially attested MTBF.
• Long product life expectancy.

Unrivalled serviceability
• Innovative maintenance thanks to brick architecture.
• Rapid repairs: 5 times faster than legacy UPS.
• Totally front access maintenance.

Embedded digital technology
• IoT ready device for access to connected services.
• eWIRE mobile app for AR guided installation and reporting.
• SOLIVE UPS mobile app for remote control and anomaly notification.
• Easy integration in LAN/WAN and virtual environments.

Certified performance
• Full performance up to 40 °C without derating and without specific conditions.
• Energy savings - without compromise: 96.5% efficiency in VFI.
• Up to 99% efficiency in “ECO” mode.
• Performance tested and verified by TÜV SÜD.

User and environmentally friendly
• Ergonomics designed to simplify usage.
• Ready for upcoming eco-regulations.
• RoHS compliant.
• Halogen-free cables.
• 25+ languages available on the mimic panel.

Extended and flexible back-up time
• High density internal battery engineering reduces footprint significantly.
• Internal battery up to 80 kW included.
• Fast recharge - even for very long back-up time.
• Li-Ion battery technology-ready.
Model Masterys BC 100 KVA

Reset default

Specification

Output Specification
Output Capacity (KVA )
100 KVA
Output Capacity (KW )
90 KW
Output Power Factor
Power Factor
Output Phase
3 Phase
Output Voltage
400 Volt
Other Output Voltage
380 Or 415 Volt
Efficiency at Full Load
> 96.5 %
Output Voltage Distortion
< 3 %
Output Frequency (sync to mains)
Output Frequency (not synced)
Load Crest Factor
Output Voltage THD
Transfer Time
< 0 ms
Output Waveform type
Output Connections
Bypass
Overload Capacity
UPS Parallel Upto
Input Specification
Other Input Voltage
Input Voltage
400 Volt
Input Phase
3 Phase
Input frequency
50 60
Input frequency Range
40 - 70 Hz
Input Voltage Range (Output Derated)
150 - 342 Volt
Input voltage range for main operations
342 - 477 Volt
Input Power Factor
Power Factor
Input Connections
Input Protection
Input Voltage THD
< 3 %
Input Short Circuit Current (Maximum)
kAmps.
Input Current (Maximum)
Amp.
Batteries & Runtime
Internal Battery Capacity (VAH)
Battery DC Bus
432 - 576 VDC
Battery Type Compatibility
Battery Position Option
External
Approved Battery Capacity (AH)
100 - 200 Amp.
Battery Circuit Breaker
Communication & Management
Control panel
SNMP Management
Power Management Software
Interface Port(s)
Audible Alarm
Audible noise at 1 meter from surface of unit
< Decibal
Physical
Maximum Height
1400 Mm
Maximum Width
444 Mm
Maximum Depth
850 Mm
Shipping Height
Mm
Shipping Width
Mm
Shipping Depth
Mm
Net Weight
0 Kg
Shipping weight
Kg
Colour
Environmental
Operating Temperature
0 - °C 40
Operating Relative Humidity
0 - % 95
Operating Elevation
- Meters
Storage Temperature
- °C
Storage Relative Humidity
- %
Storage Elevation
- Meters
Online thermal dissipation
Protection Class
Compliances
Compliance
Approvals
EN/IEC 62040-1, IEC 62040-2, IEC 62040-3, IEC 62040-4
Other Environmental Compliance
Compliant
Other Specifications
Technology
Filtering
Surge Protection
Yes

Documentation

Item Catalogue
MASTERYS GP4 Socomec Catalogue
pdf